Building envelopes

Moisture in building materials can destroy structural integrity and maintain the shape. The first step in moisture problem remediation is to quickly and accurately locate and eliminate sources of moisture. Infrared cameras show exactly what is wet and it is dry. IR instantly find the ultimate source with little or no physical disassembly of the premises and minimal disturbance of inhabitants.

Infrared thermography can provide remarkable, nondestructive information about construction details and buildings. Often the problems and their causes and their effects can be seen only after costly damage has already been done. Could be a regular at this point or point the only way out extensive and costly reconstruction.

The main building applications for infrared technology are:

Excessive use of energy that is missing or damaged insulation, thermal insulation, in which the implementation or inadequate. It is important to know what type of insulation in the construction and design details, below, was installed as insulation.
Air Leakage sites can be excessive, and make up to half of energy consumption in government buildings. Adequate ventilation is important for the health of a building. Sometimes the cause of the large leak may be able to move or poor design and construction, the air above the thermal scale.
The penetration and damage caused by leaks or condensation, in particular, walls and ceiling surfaces. Building design and technology have created more stringent heat dissipation and trapped moisture impermeable materials.
Poor plumbing supply or provision of construction and installation caused problems leading to excessive energy consumption and uncomfortable buildings.
Find Termite Infestations
Control of construction and structural development. Great progress has been made to correct reinforcement in concrete, masonry buildings and concrete-filled cell pressure is controlled.
Water leakage from pipes, either in walls or ceilings

* Delamination of the material Fasc
"Sick building syndrome, mold and health issues.
External Thermal Insulation Composite System (ETICS) design is particularly vulnerable to the ingress of water caused mold and wood decay problems.

A large amount of infrared thermography is that builders, architects, contractors and enabled inspectors to locate problems, verify and validate performance of buildings solutions. The primary return on investment in building thermography is to get a higher degree of certainty that the building be carried out as planned and the accommodations are more comfortable, often at a lower cost.